Argon/Medex Disposable IBP Transducer, Measuring Invasive Arterial Pressure

Product Details
Customization: Available
Type: Surgical Supplies Materials
Material: High Polymer Material and Electronic Chips
Still deciding? Get samples of US$ 6/Piece
Request Sample
Manufacturer/Factory & Trading Company
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
160
Year of Establishment
2009-03-20
  • Argon/Medex Disposable IBP Transducer, Measuring Invasive Arterial Pressure
  • Argon/Medex Disposable IBP Transducer, Measuring Invasive Arterial Pressure
  • Argon/Medex Disposable IBP Transducer, Measuring Invasive Arterial Pressure
  • Argon/Medex Disposable IBP Transducer, Measuring Invasive Arterial Pressure
  • Argon/Medex Disposable IBP Transducer, Measuring Invasive Arterial Pressure
  • Argon/Medex Disposable IBP Transducer, Measuring Invasive Arterial Pressure
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Company Profile
  • Exhibition
  • Certifications
  • Packaging & Shipping
Overview

Basic Info.

Model NO.
JIBPT-01-MD
Ethylene Oxide Sterilization
Ethylene Oxide Sterilization
Quality Guarantee Period
Three Years
Group
All
Logo Printing
With Logo Printing
Properties
Medical Materials & Accessories
Certificate
CE/ISO13485/TUV
Packing
40/96PCS in a Box
Flow
30ml/3ml
Other Service
OEM/ODM
Transport Package
Sterile Blister Box
Specification
224*113*45mm
Trademark
JCR
Origin
China
HS Code
9018909991
Production Capacity
200000/Month

Product Description

 Disposable IBP Transducer

1.Consistant accurate working during blood pressure monitoring.
2.100000 grade clean workshop and 100% finial test.
3.Sterile and individual pakage.
4.connectors compatible with most monitors.
5.Single/double/triple channel are options.

6.OEM/ODM are available.
7.IBP transducer with TE sensor chip
8.ISO CE approval

 

Product Description

Properties
Medical Materials & Accessories
Product Name
Argon/Medex disposable IBP transducer
Brand Name
JCR
Model Number
JIBPT-01-UT

Detailed Photos

Main technical parameters and working environment requirements:
Disposable Pressure Transducer
Barometric pressure
70~106Kpa
Relative humidity
10~90% (non-condensing)
Operating pressure range
-50 ~ + 300 mmHg
Sensitivity
5.0μV/V/mmHg ±3%
Nonlinearity and hysteresis
full-scale reading±1.5%
Input impedance
1200Ω ~3200Ω
Zero pressure offset
-20mmHg~+20mmHg
Thermal offset shift
≤±0.3mmHg/°C
Offset drift
After warm-up for 20 seconds, drift within 2 mmHg within 8 hours
Thermal span shift
≤±0.1%/°C
Frequency response
Standard pressure set (48 "/ 12") is 40 Hz; Separate sensor > 200 Hz
Defibrillator withstand
Defibrillation depends on the final connection of the equipment.
Leakage current
Leakage current is dependent on the final connection of the equipment
Overpressure load
-400~+4000mmHg
Shock resistance
Withstand falling from one meter for three times
 
Light sensitivity
When exposed to a 3400°K tungsten light, candle light at 3000 feet, it's less than 1 mmHg under rated voltage.
Storage and transport environment requirements
- 20 ° C~ + 60 ° C, < 90%(non-condensing), no corrosive gas and indoor ventilation, and to avoid high temperature and cold.
Contact with the human body
≤168h
Intra-system velocity
Flow
2-5mL/h
Intra-system velocity refers to the velocity under 6.00 VDC and 25°C, unless there are additional instructions.
Product shelf-life
3 years
Argon/Medex Disposable IBP Transducer, Measuring Invasive Arterial PressureArgon/Medex Disposable IBP Transducer, Measuring Invasive Arterial PressureArgon/Medex Disposable IBP Transducer, Measuring Invasive Arterial PressureArgon/Medex Disposable IBP Transducer, Measuring Invasive Arterial PressureArgon/Medex Disposable IBP Transducer, Measuring Invasive Arterial PressureArgon/Medex Disposable IBP Transducer, Measuring Invasive Arterial PressureArgon/Medex Disposable IBP Transducer, Measuring Invasive Arterial Pressure

Company Profile

Argon/Medex Disposable IBP Transducer, Measuring Invasive Arterial Pressure

 

Exhibition

 

Argon/Medex Disposable IBP Transducer, Measuring Invasive Arterial Pressure

Certifications

Argon/Medex Disposable IBP Transducer, Measuring Invasive Arterial Pressure

Packaging & Shipping

Argon/Medex Disposable IBP Transducer, Measuring Invasive Arterial PressureArgon/Medex Disposable IBP Transducer, Measuring Invasive Arterial Pressure


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier